Feature:It has good sensitivity to ozone in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc.
Production Description:
Sensitive material of MQ131 gas sensor is semiconductor metallic oxide, which with high conductivity in clean air. When the ozone gas exists, the sensor’s conductivity gets lower along with the gas concentration rising. Users can convert the change of conductivity to correspond output signal of gas concentration through a simple circuit. MQ131 ozone gas sensor has high sensitivity to ozone and also has sensitivity to strong oxide gases, such as Cl2, and NO2 etc. It responses oppositely to organic interference gases, compared with O3.
Feature:
It has good sensitivity to ozone in wide range, and has advantages such as long lifespan, low cost and simple drive circuit &etc.
Application:
It is widely used in domestic ozone concentration alarm, industrial ozone concentration alarm and portable ozone concentration detector.
Main technical parameters:
Low concentration:
Model |
MQ131 |
||
Sensor Type |
Semiconductor |
||
Standard Encapsulation |
Plastic cap |
||
Target Gas |
Ozone |
||
Detection range |
10~1000ppb Ozone |
||
Standard Circuit Conditions |
Loop Voltage |
Vc |
5.0V±0.1V DC |
Heater Voltage |
VH |
5.0V±0.1V AC or DC |
|
Load Resistance |
RL |
Adjustable |
|
Sensor character under standard test conditions |
Heater Resistance |
RH |
35Ω±3Ω (room temp.) |
Heater consumption |
PH |
≤800mW |
|
Sensitivity |
S |
Rs(in 200ppb O3)/Rs(in air)≥2 |
|
Output Voltage |
△Vs |
≥1.0V(in 200ppb O3) |
|
Concentration Slope |
α |
≤0.6(R100ppb/R500ppbO3) |
|
Standard test conditions |
Temp. Humidity |
20℃±2℃;55%±5%RH |
|
Standard test circuit |
Vc:5.0V±0.1V; VH: 5.0V±0.1V |
||
Preheat time |
Over 48 hours |
||
Oxygen content |
21% (not less than 18%, (oxygen concentration will affect the initial value, sensitivity and repeatability of the sensor, please consult when using it under low oxygen concentration) |
||
Life span |
5 years |
High concentration
Model |
MQ131 |
||
Sensor Type |
Semiconductor |
||
Standard Encapsulation |
Bakelite, Metal cap |
||
Target Gas |
Ozone |
||
Detection range |
10~1000ppm Ozone |
||
Standard Circuit Conditions |
Loop Voltage |
Vc |
5.0V±0.1V DC |
Heater Voltage |
VH |
5.0V±0.1V AC or DC |
|
Load Resistance |
RL |
Adjustable |
|
Sensor character under standard test conditions |
Heater Resistance |
RH |
30Ω±3Ω (room temp.) |
Heater consumption |
PH |
≤950mW |
|
Sensitivity |
S |
Rs(in 300ppm O3) / Rs(in air)≥2 |
|
Output Voltage |
△Vs |
≥1.0V(in300ppm O3) |
|
Concentration Slope |
α |
≤0.6( R10ppm/R100ppm O3) |
|
Standard test conditions |
Tem. Humidity |
20℃±2℃;55%±5%RH |
|
Standard test circuit |
Vc:5.0V±0.1V; VH: 5.0V±0.1V |
||
Preheat time |
Over 48 hours |
||
Oxygen content |
21% (not less than 18%, (oxygen concentration will affect the initial value, sensitivity and repeatability of the sensor, please consult when using it under low oxygen concentration) |
||
Life span |
5 years |
We provide Worldwide Shipping by DHL, Fedex, Standard shipping (China Post e-Packet) and some other shipping ways on ALL ITEMS!
2. SERVICE TRANSIT TIME is provided by the carrier.- Reference Delivery time (working days):
- DHL:3-7 days
- Fedex:3-7 days
- China Post e-Packet : 15-35 days
Transit times may vary, particularly during the holiday season.
We suggest you choose Expedited Shipping(DHL or FedEx) to ensure the products reach your home fast & safety.
3. ORDERS PROCESSED TIMELY after the payment verification.We do our best to process & ship all orders as soon as possible. Most orders are processed within 48 hours.
Note:a.We only ship to confirmed order address. Your order address MUST MATCH your shipping address.
b.We accept DROP SHIPPING. You can leave us your customer’s address, when you place an order,then your customers can get the goods directly.
4. PACKAGE STATUS TRACKINGTracking and secure checkout are provided for all orders. https://www.17track.net/en - this tracking website can help you track the status of your package.
Note:Sometimes you may can't get your package within expected time, please be patient for a few more days. Because we can't control the delivery time or condition when package on shipping. Certainly, we are glad that you can contact us for help. Our goal is to make customer satisfied!
Dear valued friends,
If you have any questions, our Customer Service staffs will be very glad to help you. We try our best to reply to your emails ASAP, however, due to high volume of daily incoming emails and time zone difference, we may not be able to reply your emails immediately. Please allow 24 business hours for us to response. And you can also call us in +86-18595618735 or email us to enquiry@winsensor.com.
Thank you for your support, I hope everyone has a pleasant business trip in our store, and welcome you to come next!
If you buy more quantity, please contact us.Buy multiple products by the "Add to cart" we will make the discount for you.