{"product_id":"frn03p-flow-sensor","title":"1PC FRn03P Flow Sensor","description":"\u003cp\u003eThe FRn03P series micro flow gas mass flow sensors are specifically designed for various micro-flow process control applications. This series of products utilizes the MEMS thermal principle and is suitable for dry, clean gases. The sensor features surface-mount installation, making it particularly suitable for multi-sensor integration in confined spaces.\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 class=\"text-6 pb-2\"\u003eApplication\u003c\/h4\u003e\n\u003cp\u003eThe sensor features surface-mount installation, making it particularly suitable for multi-sensor integration in confined spaces.\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 class=\"text-6 pb-2\"\u003eFeatures\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHigh sensor sensitivity with very low start-up flow\u003c\/li\u003e\n\u003cli\u003eSurface-mount installation, compact structure\u003c\/li\u003e\n\u003cli\u003eMultiple signal output options\u003c\/li\u003e\n\u003cli\u003eHigh stability and repeatability across the full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"text-6 pb-2\"\u003eSpecifications\u003c\/h4\u003e\n\u003cdiv class=\"table-container\"\u003e\n\u003ctable class=\"table table-hover table-bordered\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eValue\u003c\/td\u003e\n\u003ctd\u003eUnit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eFlow Measurement\u003c\/td\u003e\n\u003ctd\u003eMaximum Flow\u003c\/td\u003e\n\u003ctd\u003e50\/100\/200\/300\/400\/500 1000\/2000\/3000\/4000\/5000\u003c\/td\u003e\n\u003ctd\u003eSCCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±（2+0.5FS）\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.50\u003c\/td\u003e\n\u003ctd\u003e%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Working Pressure\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003ekPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Drop at Max. Flow\u003c\/td\u003e\n\u003ctd\u003e≤60 ≤1000\u003c\/td\u003e\n\u003ctd\u003ePa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0～50\u003c\/td\u003e\n\u003ctd\u003e℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003eOutput Mode\u003c\/td\u003e\n\u003ctd\u003eDigital I²C and Analog 0.5V～4.5VDC\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI²C Communication Rate\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003ekHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Response Time\u003c\/td\u003e\n\u003ctd\u003e≤50\u003c\/td\u003e\n\u003ctd\u003ems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eElectrical Parameters\u003c\/td\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5～15\u003c\/td\u003e\n\u003ctd\u003eVDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Current\u003c\/td\u003e\n\u003ctd\u003e≤30\u003c\/td\u003e\n\u003ctd\u003emA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Interface\u003c\/td\u003e\n\u003ctd\u003ePH2.0-5P Plug-in Connector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOthers\u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20～65\u003c\/td\u003e\n\u003ctd\u003e℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Medium\u003c\/td\u003e\n\u003ctd\u003eDry, clean non-corrosive gases\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003eThe company's flow sensors are calibrated by default using air at 20℃, 101.325 kPa. Production conditions are temperature 22±2℃, cleanroom, (30%～35%) RH environment. If special requirements exist, calibration is performed according to customer requirements.\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e* The description and specifications might be changed without notice. Please contact us for the latest information before placing orders.\u003c\/p\u003e\n\u003c!----\u003e","brand":"Winsen","offers":[{"title":"100SCCM","offer_id":48329440985280,"sku":null,"price":83.6,"currency_code":"USD","in_stock":true},{"title":"200SCCM","offer_id":48329441018048,"sku":null,"price":83.6,"currency_code":"USD","in_stock":true},{"title":"300SCCM","offer_id":48329441050816,"sku":null,"price":83.6,"currency_code":"USD","in_stock":true},{"title":"400SCCM","offer_id":48329499082944,"sku":null,"price":83.6,"currency_code":"USD","in_stock":true},{"title":"500SCCM","offer_id":48329499115712,"sku":null,"price":83.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0611\/8008\/4416\/files\/frn03p.jpg?v=1779868337","url":"https:\/\/shop.winsen-sensor.com\/products\/frn03p-flow-sensor","provider":"Winsen Electronics","version":"1.0","type":"link"}